Ürünler / Coval - Vacuum managers

Island assembly consisting of 1 Heavy Duty Vacuum Pump GVMAX HD Series with SMART SWAP quick-mounting system, left lateral pressure connection, max. vacuum 85 %, 2.5 mm nozzle dia., vacuum controlled 24 V DC NO and controlled blow-off 24 V DC NC , 2 connectors M12 4-pin, with powerful blow-off.
ref. : GVMAXHD90X25VC24A2XG1F2DRB1L
characteristics
type of product (typp) venturi
Nozzle diameter (Ø) 2.5mm
Air drawn in (aa) 185Nl/min
Generator Control (PG) NO/NC
Connection (Cx) 2 x M12-4pin
for islands mounting (Ilot) 1 module
Air consumed (ca) 294Nl/min
Blow-off (S-SP) Powerful
models (mod) Left lateral pressure connection
Maximum vacuum (mv%) 85%
Dimensions
Characteristics
Pneumatic diagram
Model GVMAXHD__V: vacuum pump with NO vacuum control and NC blow-off.
In the event of power failure, vacuum is still generated: object is held in place => fail-safe.
In the event of compressed air failure, the vacuum is no longer maintained.
• NO vacuum control solenoid valve
• NC blow-off control solenoid valve
• Blow-off controlled by external signal
Electrical connections
(1) 24 V DC suction command, depending on version:
- S: 24 V DC vacuum control
- V: 24 V DC vacuum off command
- L: 24 V DC vacuum control with min. pulse-triggering of 50 ms

(2) DO2 configurable: - ASC status (default)
- or Pressure fault (below 5 bar or above 8 bar)
- or Power supply fault (below 21.6 V or above 26.4 V)
- or ASC fault
- or Object lost L: 24 V DC vacuum control with min. pulse-triggering of 50 ms
Blow-off
Powerful blow-off (version GVMAXHD…F2)
This type of blow-off allows for objects to be quickly released in the event that the pump cannot be placed as close as possible to the suction cups, or to reduce the cycle time as much as possible.
The isolation valve F directs the entire blow-off flow towards the suction cups. In this case, the blow-off pressure is identical to the vacuum pump’s compressed air supply pressure.
3D Model

To generate the 3D file in the required format, we use the TRACEPARTS platform. To download the file, please use your TRACEPARTS username and password.